OC-25×3™

Catalogue No.

OC-25×3™
  • Description
  • Graph Details

Supplier

MaxCyte

|

Catalogue No.

OC-25×3™

Processing Assemblies

Static electroporation processing assemblies for research applications in small volume scales with both single-well and multi-well options.

Small-scale RUO Processing Assemblies

Static electroporation processing assemblies for research applications in small volume scales with both single-well and multi-well options.

Research Use Only (RUO) Processing assemblies aid the discovery and development of applications at small scales. These static electroporation consumables are made from high-grade, inert materials to protect precious cells with additional design features for easy sample loading and recovery.

OC-25×3™

  • Small volume for limited cell number applications
  • Multi-well for increased throughput; lower cost per transfection
  • V-shaped well design for efficient cell recovery

 

Configuration: 3-well, 25 µL maximum volume per well
Cell Range: 1×10⁵ – 5×10⁶ per well
Volume Range: 20 – 25 µL per well
Application: Research Use Only
Catalog: SOC-25×3
Compatible with: ATx™ and STx™

  • Description
  • Graph Details
Description icon

Static electroporation processing assemblies for research applications in small volume scales with both single-well and multi-well options.

Small-scale RUO Processing Assemblies

Static electroporation processing assemblies for research applications in small volume scales with both single-well and multi-well options.

Research Use Only (RUO) Processing assemblies aid the discovery and development of applications at small scales. These static electroporation consumables are made from high-grade, inert materials to protect precious cells with additional design features for easy sample loading and recovery.

OC-25×3™

  • Small volume for limited cell number applications
  • Multi-well for increased throughput; lower cost per transfection
  • V-shaped well design for efficient cell recovery

 

Configuration: 3-well, 25 µL maximum volume per well
Cell Range: 1×10⁵ – 5×10⁶ per well
Volume Range: 20 – 25 µL per well
Application: Research Use Only
Catalog: SOC-25×3
Compatible with: ATx™ and STx™

Graph Details icon

Graph Details: K562 cells were suspended in MaxCyte® Electroporation Buffer with pGFP at low concentration (200 µg/mL) or high concentration concentration (400 µg/mL) and transfected in replicates of 2 processing assemblies using low, medium and high electroporation energy. GFP fluorescence was assessed by flow cytometry 24 hours after electroporation.

 